Each technology has its own inclusion and exclusion criteria. Please review the cards below before your first session.
Light · Laser
Photobiomodulation
Low-level laser therapy (LLLT) · Red & near-infrared LED
- Active cancer or history of tumour photosensitivity
- Direct application on the eyes (protection mandatory)
- Areas with non-compatible photosensitive implants
- Pregnancy (avoid lumbar and abdominal exposure)
- Use of photosensitising medication (tetracyclines, isotretinoin…)
- Photosensitive epilepsy
- Active skin conditions on the treated areas
- Well-controlled diabetes · compatible with monitoring
- Post-operative scarring · beneficial on medical prescription
Brain · EEG
Neurofeedback
Real-time EEG biofeedback brain training
- Uncontrolled epilepsy (some protocols contraindicated)
- Acute psychosis or ongoing dissociative episode
- Bipolar disorder · requires advice from the treating psychiatrist
- Use of psychotropics (benzodiazepines, antipsychotics) · protocol adaptation
- ADHD with ongoing stimulant treatment · medical coordination required
- Recent head trauma (less than 6 months)
- Generalised anxiety · indicated and well tolerated
- Sleep disorders · documented scientific results
Heart · Coherence
HRV Biofeedback
Heart rate variability · Cardiac coherence
- Severe untreated cardiac arrhythmia
- Pacemaker carriers (some devices incompatible · verification required)
- Heart failure · cardiologist advice required
- Severe uncontrolled high blood pressure
- Post-infarction recovery (less than 3 months)
- Chronic stress and burnout · indicated as first-line treatment
- Mild to moderate, well-controlled hypertension · beneficial
Composition · Body
Bioimpedance analysis
Body composition analysis by electrical bioimpedance
- Pacemaker or implantable defibrillator carriers
- Electroconductive metal prostheses (some models)
- Pregnancy · measurement not recommended, results unreliable
- Significant fluid retention (oedema, ascites)
- Renal insufficiency · results to be interpreted with caution
- Overweight and obesity · compatible and indicated
- High-level athletes · valid and accurate measurement
Drainage · Circulation
Pressotherapy
Sequential pneumatic compression of the lower limbs
- Acute or recent deep vein thrombosis (DVT)
- Decompensated heart failure
- Skin infection or open wound on the treated areas
- Active malignant tumour in the compressed areas
- Pregnancy · to be avoided in the first trimester
- Diabetes with advanced peripheral neuropathy
- Anticoagulants (warfarin, DOACs) · medical advice required
- Mild chronic venous insufficiency · highly indicated
- Sports recovery · validated protocol
Breathing · O₂
Oxygen therapy
Inhalation of enriched oxygen · EWOT (Exercise With Oxygen Therapy)
Device used: Y-X02W concentrator · PSA method (Pressure Swing Adsorption) · Oxygen purity 93% ±3% · Adjustable flow 1 to 10 L/min · Atmospheric pressure 86 to 106 kPa (normobaric) · Integrated dual humidification
- Severe COPD (chronic hypercapnia)
- Stage IV COPD with hypoxic drive dependence · risk of respiratory depression
- Active or recent pneumothorax
- Certain ophthalmic conditions (oxygen-dependent retinopathy)
- Children under 3 years of age · no adapted protocol available
- Severe claustrophobia · the mask may trigger an anxiety attack
- Uncontrolled asthma · medical supervision mandatory
- Pregnancy · obstetrical advice required
- Hyperthyroidism · increased monitoring
- Epilepsy · some protocols not recommended
- Chronic fatigue and lack of energy · indicated
- Athletic performance and recovery · validated protocol
Effort · Heat
Infrared HIIT
High-intensity interval training in an infrared environment
- Severe uncompensated cardiovascular disease
- Active fever or acute infection
- Heating metal implants in exposed areas
- Uncontrolled high blood pressure
- Pregnancy · not recommended beyond the 1st trimester
- Unbalanced hypothyroidism or hyperthyroidism
- Multiple sclerosis (heat may temporarily worsen symptoms)
- Overweight · documented effectiveness with supervision
Light · Sleep
Light therapy
Exposure to broad-spectrum white light · Circadian regulation
Two devices used: fixed light panels (10,000 lux) and Luminette 3 (mobile light glasses). The contraindications apply to both devices · no scientific difference.
- Active eye disease (AMD, unstabilised glaucoma, retinopathy)
- Use of photosensitising medication
- Bipolar disorder · risk of manic switch, psychiatric advice required
- Photosensitive epilepsy
- Systemic lupus erythematosus (photosensitivity)
- Seasonal depression · first-line treatment
- Circadian shift and shift work · highly effective
Light · Consciousness
Dream Machine
Stroboscopic photostimulation · Induction of altered states of consciousness
- Epilepsy or history of seizures · risk of triggering by repeated light stimulation
- Minors under 18 years of age
- Pregnancy
- Active eye conditions: AMD, unstabilised glaucoma, retinopathy, recent eye surgery (less than 3 months)
- Severe psychiatric history: psychosis, schizophrenia, dissociative disorder
- Uncontrolled neurological disorders
- Migraines with aura
- Bipolar disorder · risk of manic switch, psychiatric advice required
- Use of photosensitising medication
- Severe anxiety or claustrophobia · the experience can be destabilising
- History of psychological trauma · altered states may reactivate it
- Chronic stress and burnout · indicated in the Wired protocol
- Sleep disorders · documented sleep sessions
- Difficulty mentally disconnecting
⚠ Scientific note: The Dream Machine induces altered states of consciousness with visual hallucinatory phenomena. Clear prior information and a signed informed consent form are mandatory before any session. Use is not recommended in a B2B context without a reinforced prior information protocol.
Field · Cellular
PEMF
Low-frequency pulsed electromagnetic fields · Power Mat Charlotte Muller
- Pacemaker carriers or active electronic implants
- Pregnancy · avoid abdominal exposure
- Active tumour in the treatment area
- Ferromagnetic metal implants in the treated area
- Epilepsy · some protocols to be adapted
- Severe low blood pressure
- Coagulation disorders
- Stress, anxiety, hyperactivity of the nervous system · highly indicated
- Mild to moderate sleep disorders
- Chronic and inflammatory pain
- Post-exercise recovery
Relaxation · Nervous system
Neuro-relaxation
Sonic vibration · Gentle somato-sensory stimulation
- Acute psychiatric disorders
- Marked sensory hypersensitivity
- Stress, anxiety, hyperactivity of the nervous system · highly indicated
- Mild to moderate sleep disorders
- Post-exercise and post-stress recovery
Muscle · Electrostimulation
Bodysculpt / EMS
High-intensity muscle electrostimulation (HIFEM / EMS)
- Pacemaker or implantable defibrillator carriers
- Metal implants in the treated areas
- Pregnancy
- Severe disc herniation or unstable spinal pathology
- Epilepsy · neurological advice required
- Active cancer · not recommended on treated areas
- Coagulation disorders or anticoagulants
- Post-immobilisation muscle atrophy · highly indicated
Imaging · Diagnostic
Thermography
Non-invasive infrared imaging · Body thermal assessment
- Application of creams or cosmetics within 4 hours before the session · falsified results
- Intense physical activity less than 4 hours before the session
- Sun exposure or hot bath less than 2 hours beforehand
- Non-invasive · no known absolute contraindication
- Compatible with all medical conditions (passive imaging)
- Pregnancy compatible
Nutrition · Supplements
Micronutrition & Supplementation
Targeted supplementation based on individual biological profile
- No supplement prescribed without prior biological assessment
- Renal insufficiency · dosages must be adapted
- Hepatic insufficiency · supplement metabolism altered
- Possible drug interactions (anticoagulants, immunosuppressants)
- Pregnancy and breastfeeding · specific protocol under supervision
- Known food allergies · systematic verification of excipients
- All supplementation is validated by our reference physician